AC/DC Voltage Tester
ET45
- Tests AC voltages from 24V to 240V AC at four useful levels
- Tests DC voltages from 32V to 330V at four levels
- Built-in test lead holder on back of tester holds the leads in one of two positions: one so that they are spaced correctly to test tamper-resistant US-style outlets and the other for convenient storage of the test leads
- Test leads can be docked in the holder for convenient storage
- Batteries not required; tester is powered by the applied voltage
- Built to withstand a 9.8-Foot (3 m) drop
- Safety Rating: CATIII 350V, Class 2, Double insulation
- Ingress protection IP44 dust and water resistant
- Pocket clip secures tester to pocket for reliable everyday carrying
Klein Tools ET45 is an Electronic Voltage Tester. Designed as a simple, easy to use tester to check, verify or troubleshoot common residential electrical wiring in electrical outlets, light fixtures, doorbells and more. This tester does not require batteries, and features a pocket clip for convenient carrying.
Specifications
Type:
Electronic Products
Application:
Measures AC/DC Voltage
Special Features:
Built-in Test Lead Holders on Back of Tester Spaced Correctly to Hold Leads for Testing Tamper-Resistant US-style Outlets
Material:
Plastic Housing, PCB with Electronic Components
Drop Protection:
9.8' (3 m)
Display:
Analog LED
Voltage:
AC Level Indicators: 24V, 48V, 120V, 240V; DC Level Indicators: 32V, 64V, 160V, 330V
Frequency:
50/60 Hz
Ingress Protection:
IP44
Pollution Degree:
2
Tests Continuity:
No
Accuracy:
Typically at >90% of the Indicated Range (Except for 24V AC / 32V DC, >95% of Range)
Integral Lead Storage:
Yes
Interchangeable Leads:
No
Lead Length:
9'' (23 cm)
Standard:
CATIII 350V, CE
Included:
Tester
Overall Length:
4.45'' (11.3 cm)
Overall Height:
1.19'' (3 cm)
Overall Width:
1.05'' (2.7 cm)
Weight:
1.8 oz (52.0 g)
UPC:
092644691843
Warnings
- Read, understand, and follow all instructions, cautions and warnings attached to and/or packed with all test and measurement devices before each use.
- Before each use, verify tester operation by measuring a known voltage.
- Never use the tester on a circuit with voltages that exceed the category based rating of this tester.
- Always adhere to local and national safety codes. Use personal protective equipment to prevent shock and arc blast injury where hazardous live conductors are exposed.
- Usage of this tester in any way other than that specified by the manufacturer can impair safe operation, resulting in severe injury or death.